Home
Products
News
Company News
Industry News
Blog
Case
Software
Hardware
Factory Show
Contact Us
About
×
×
Home
Products
News
Company News
Industry News
Blog
Case
Software
Hardware
Factory Show
Contact Us
About
×
Search
Home
>
Products
>
Programmable High low temperature test chamber
>
Programmable high and low temperature testing machine
Product Categories
Programmable High low temperature test chamber
Programmable constant temperature and humidity test machine
Programmable high and low temperature testing machine
Rapid temperature change testing machine
High temperature testing machine
Programmable constant temperature humidity test chamber
Three box thermal shock testing machine
Two box thermal shock testing machine
Rapid temperature humidity change test chamber
Cat 5e Network Cables
Temperature shock test chamber
UL 1007 Wire And Cables
High temperature test chamber
European VDE Power Cords
Double door test chamber
Explosion-proof test chamber
BS-225CD-5F
Email
Equipment Model: BS-1000AD
Effective Volume: 1000L
Internal Chamber Dimensions: 100010001000 (WHD) (mm)
External Chamber Dimensions:
Front-rear structure: approximately 125019201950 (WHD) (mm)
Left-right structure: approximately 185019001450 (WHD) (mm)
(Subject to the final confirmed 3D drawing)
Temperature Range: -40℃~150℃
Humidity Range: 20~98%R.H
Temperature and Humidity Comparison Table
Heating Rate: -40℃ ~ 150℃ ≥3℃/min (Non-linear throughout the process, no-load acceptance)
Cooling Rate: 150℃ ~ -40℃ ≥1℃/min (Non-linear throughout the process, no-load acceptance)
Temperature and Humidity Display Accuracy: Temperature: 0.01℃; Humidity: 0.1%R.H
Temperature and Humidity Deviation:
Temperature: ±2℃
Humidity: When ≥75%RH, ≤+2-3%R.H; When <75%RH, ≤±5%R.H
Temperature and Humidity Fluctuation:
Temperature: ≤±0.5℃
Humidity: +2/-3%R.H
Temperature and Humidity Uniformity:
Temperature: ≤2℃
Humidity: +2/-3%R.H
Cooling Method: Air-cooled
Equipment Weight: 400KG
Equipment Power: 380V 11.5KW
Others:
The above performance indicators refer to data measured under the conditions of no load, no test samples, and ambient temperature of 25±2℃
70dB (1 meter away from the chamber door, at a height of 1.5 meters)