Effective Volume: 42L
Inner Box Dimensions: 400×350×300 (W×H×D) (mm)
Outer Box Dimensions: Approximately 1400×1873×1655 (W×H×D) (mm)
Temperature Range:
-
High-temperature zone: RT ~ 170℃
-
Low-temperature zone: RT ~ -60℃
-
Test zone: -40 ~ 150℃
Temperature Shock Range:
-
High temperature: 60℃ ~ 150℃
-
Low temperature: -10℃ ~ -40℃
-
Normal temperature: Indoor temperature
Temperature Shock and Recovery Time:
-
Temperature shock time: 5S
-
Temperature recovery time: 5 minutes
-
Shock process (as shown in the figure)
The green line represents the heat storage curve of the high-temperature zone, the red line represents the shock curve of the test zone, and the blue line represents the cold storage curve of the low-temperature zone.
Temperature Fluctuation: ≤±0.5℃
Temperature Error: ≤±2℃
Temperature Uniformity: ≤±2.0℃ (Temperature uniformity is the arithmetic mean of the difference between the measured maximum and minimum temperatures in each test)
Heating Rate of Preheating Zone: ≥3℃/min (non-linear throughout the process)
Cooling Rate of Precooling Zone: ≥1℃/min (non-linear throughout the process)
Functional Requirements:
Equipment Weight: 550KG
Equipment Power: 380V 18KW
Note: The above performance indicators are measured under the conditions of ambient temperature +25℃, relative humidity ≤85%RH, and no test samples.
This test equipment is prohibited from: